...
GB – BillReadsAgainstSelfReadChannel
Compares the invoice meter readings against meter readings entered into Non-Periodic Channels.
Configuration of this validator requires meter serial number(s) to be entered into the Sigma bill entry screen and meters to be setup with Non-Periodic Channels against Sites.
...
This Validator checks the consumption entered in the bill against the non-periodic self read channel.
It looks at both the reading values and dates from each channel. It will accrue from the two previous self-reads to match the most recent bill date, giving an accurate reading of what the self read value would have been on the day the bill was issued.
This highlights any errors that could have generated from either source.
The Validator requires the following for it to work:
- The Account and the Meter both need to be in a Supply Point
- The Meter Serial Number to be entered into the Sigma bill entry screen
- The Meter to have a Non-periodic Channel
- The Non-periodic Channel to have a Property Key (ELECTRIC only)
The Account and the Meter both need to be in a Supply Point
The Meter Serial Number to be entered into the Sigma bill entry screen
- Enter the Meter Serial Number in the Meter number field when creating the bill (or it will be automatically entered via the EDI File)
- Note: Once this has been added to a bill, it will automatically show on the next bill that is added
The Meter to have a Non-periodic Channel
Click here to see details on adding a Channel
The Non-periodic Channel to have a Property Key (ELECTRIC only)
- Click here to see details on adding a Property Key
Validator Set up
...
Variable | Description | |
---|---|---|
Tolerance limit (%) | Enter the required tolerance percentage, ie 10 (for 10%) |
Bill Entry screen - Gas Channel Data - Gas
Failure Prompts
Gas Failure Prompt
Water worked!
Self read comparison results: Bill read value '9800' - 9800 is the meter reading entered in the bill10001' differs from self read channel projection '8624.82000' (97M409836AVal2) - 8624.8 is the projected meter reading using the data in the non periodic channel
Gas wouldnt work
Electricity wouldnt work (Electricity need a property key, see other online help page for more infor - The meter reading value entered into the present read field (10001) and the project from the Non Periodic Channel (2000). In brackets, the name of the Non Periodic Channel
Water worked, but i cant get the electric to . It has a property key on the Non Periodic channel and the supply point is valid