TB - totalConsumptionTolZeroCheck.xml

Checks zero consumption on this bill and/or previous bill

Validator Set Up


Variables

VariableDescription
Tolerance % for consumption variation on previous Tenant Bill, if both non-zero:Percentage variance allowed where current bill and previous bill consumption greater than zero
PASS if present bill = zero, previous bill = zero (bzz)

Select if validation should pass where both current and previous bills are zero

bzz – pass if this bill and the previous bill both have zero consumption
PASS if present bill = zero, previous bill non zero (bznz)

Select if validation should pass where the current bill is zero but the previous bill has consumption e.g. where property is now empty

bznz – pass if this bill has zero consumption, previous bill has consumption
PASS if present bill = non-zero, previous bill zero (bnzz)

Select if validation should pass where current bill has consumption and previous bills are zero e.g. property was previously empty

bnzz – pass if this bill has consumption, previous bill has zero consumption

PASS if cons difference % fails but kWh trivial, below significance limit (ignored if 0)

Enter a kWh value that can be used if the validator fails but by a small amount e.g.

Main tolerance set to 10% and 500 kWh significance limit:

Current cons = 4975 kWh

Previous cons = 4500 kWh

Difference = 475

This fails 10% tolerance as 4950 is the limit, but passes as less than 500 significance limit

If the user leaves the value as 0 then the bill would just FAIL on the breach of 10% (> 450)

Current Bill details


Failure Prompt

Explanation: 

Total cons within % of previous Tenant Bill. PASS/FAIL on selected bill = zero criteria: FAILED

kWhLimit=0.00  - the 'Pass if cons difference%' figure in the Validator (last field) = 0

TolPcent=0.00 - the 'Tolerance' set in the Validator (first field) = 0

LoLimit=34.6 - the consumption in the previous bill (in kWh)

bznz=0.00 -  - 0 = not set in this validator, but if ticked, will pass if this bill has consumption and the previous bill has zero consumption 

HiLimit=34.653  - the consumption in the previous bill (in kWh)

bzz=0.00 0 = not set in this validator, but if ticked, will pass if this bill and the previous bill both have zero consumption 

PrevCons=34.653 - consumption on the previous bill 34.653  kWh    (therefore did not pass validation as the previous bill has consumption of 34.653)

bnzz =1.00  - 1 = set in this validator and will pass if this bill has consumption, and the previous bill has zero consumption  

kWhDiff=4333.347 - the difference between this bills consumption and the previous bills, 4368 (this bill) - 34.653 (previous bill) = 4333.347 

PresCons=4368 - consumption in this bill