Bill Entry screen - Electricity 


Channel Data - Electric

 Image RemovedImage Added


Failure Prompt (Electricity)

...

(E12345) - The name of the Meter

Explanation

Bill Details

  • The Bill has a Meter reading value of 12345 (previous reading) as of 1/2/2020 (From date)
  • The Bill has a Meter reading value of 15000 (present reading) as of 28/2/2020 (Reading date)
  • Number of days in the bill = 28

Channel Details

  • The nearest date in the Channel to the from date of the bill is  1/2/2020, with a reading of 11000
  • The nearest date in the Channel to the to date of the bill is 1/3/2020, with a reading of 12000   (1000 units used in 28 days)
  • 1000 units / 28 days = 35.714 units per day between the two best available dates in the Channel

Calculation

35.714 units (the amount of units between dates in the Channel) x 27 (not 28 for some reason) (the number of days in the bill) = 964.3 (the predicted advance for the billing period)

964.3 units (the predicted advance for the billing period) added to 12345 (the previous reading in the bill) = 13309.3  (validator shows 13308.4)