Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.



GB – AverageppuThreshold

Checks the  pence per unit value on the current bill is less than defined ppu limit.

...

The threshold is set in the Validator is 10.5, but on this bill the average ppu was 10.91006 therefore it failed

GB – BillAgainstAssociatedData Image Removed

Compares any figure in Sigma that changes over time against a figure in an Associated Channel. For example, comparing the Flexible Gas PPU against a Channel attached to an Account.

Configuration of the validator requires an Associated Data Channel for each Account, containing the PPU.

Image Removed

Set Up:

...

This is the cell that you want to check, for example the first line of a Gas bill.  To find this number open a bill of the correct commodity.  Click on Show Bill Tags  

Image Removed

The figure in the field will change to show you the tag number.  Click Show bill  tags again to return to the entered figure

Image Removed

In this example the number to enter would be 2201

...

This is in the Associated Data Type Channel. Check the field Data type that has been chosen.  Enter this exactly as it is in the Channel.  For example, PPU Day Rate

Image Removed

...

 Use Image Removed to choose the actual Items, such as the Account  (NOT Mandatory)

...

GB – BillConsumptionAgainstHHMeters Image Removed

This Validator is for Electricity bills only.  It compares the invoice consumption against the  metered consumption entered into Periodic Channels.

It requires a Meter/Virtual Meter (and Periodic Channel) to be attached to the same Supply Point as the Account.

The Validator compares the total billed consumption (on the bill) with the total meter consumption (in the Periodic Channel).

Allows for a % tolerance of difference.

Image Removed

Set Up:

...

GB – BillInvoiceNumber

Stops an invoice being saved if no invoice number has been entered. It can also be used to ensure that specific invoice number details are entered.

Image Removed

GB – BillReadsAgainstSelfReadChannel Image Removed

Compares the invoice meter readings against meter readings entered into Non-Periodic Channels.

Configuration of this validator requires meter serial numbers to be entered into the Sigma bill entry screen and meter objects to be setup with Non-Periodic Channels against Sites.

Allows for a % tolerance of difference.

Image Removed

GB – CalcVATvsDeclaredVAT Image Removed

Compares the VAT declared on the invoice against the VAT amount calculated based on the billing data – any difference will be highlighted.

Image Removed

GB – CapacityAgainstSupplyPoint

Compares the capacity on the bill against the capacity allowance stored within the Supply Point. Add the supply capacity to your associated data: Nominated kVA which is located within the Supply Point.

Image Removed

GB – CapacityTolerance Image Removed

Compares the capacity declared on the current invoice to the capacity declared on the previous invoice and fails if it is not within a specified tolerance.

Image Removed

GB – ClosedSiteAccount Image Removed

Prevents invoices being entered if the Site or Account is closed. There are two settings to consider when applying this validator.

  • Check for active account box – will simply fail the validation if the account is not flagged as Active.
  • Allow bills prior to site closed date – will check the To date of the current bill and compare it to the closed date of the site. If the To date is later than the closed date it will fail validation.

Image Removed

GB – ConcurrentReads

 Fails an invoice if the meter readings entered do not follow on from previous invoice. It will also fail if the meter reads do not match the following invoice (if historic invoice). This validator cannot be set to Severe as it is unable to cope with missing bills.

Image Removed

GB – ConsecutiveEstimates Image Removed

Fails an invoice if the specified number of consecutive estimates is reached.

It reminds you that you need to send an actual reading to the supplier so that an Actual reading appears on the invoice.

Image Removed

Set Up:

...

GB – ConsumptionOnBillLastBillZero Image Removed

 Checks that the value of consumption is still zero if there was zero consumption on the previous bill.

Image Removed

GB – CorrFactorsvsPrevious

Checks the gas correction factor matches that of the previous bill. 

Image Removed

GB – DailyConsumptionTolHIGH Image Removed

Checks the average daily consumption of current invoice and compares against previous invoice. If the difference is greater than the tolerance set in the validator then the invoice will fail. Possible reasons for the validation to fail are:

  • Actual invoice after estimate
  • Current invoice period greater or less than previous invoice
  • Seasonal changes

Image Removed

GB – DailyConsumptionTolYear Image Removed

Same as GB – dailyConsumptionTol but instead of comparing invoice against previous invoice, this validator compares invoice against previous year. This allows for better benchmarking. The tolerance for variation can be set as a %.

GB – ElecBandppu Image Removed

Compares a band rate on current invoice against the same band rate on previous invoice. It will fail if the tolerance in the validator is exceeded. This is used to identify price increases. The tolerance default is 1pence.

GB – ElecBandppuThreshold

Sets a threshold for a band rate (Band A, B, etc.) The validator fails if the threshold is exceeded.

GB – ElecFixedCharges

Calculates set daily amount for fixed charges based on calculated number of days in the billing period. It will fail if the value is higher than the threshold set.

GB – ElecInvoicedvsCalc

Compares the total value of the electricity invoice (as calculated by Sigma) against the total value declared on the invoice. It allows for a % difference, if % difference is exceeded then query should be raised.

GB – ElecppuThreshold Image Removed

Same as GB – ElecBandppuThreshold however, instead of band rate this uses the average pence per unit which can be applied across all accounts.

GB – ElecppuvsPropertyKeyExact

Compares a property key against the electricity invoice band rate and passes the invoice if the band rate and property key matches. The property keys have the pence per units stored – these are setup on each Account.

GB – ElecppuvsPropertyKeyPct

Same as GB – ElecppuvsPropertyKeyExact but allows for a tolerance.

GB – ElecVAT%Check Image Removed

Checks the expected VAT rate – with the ability to have a % tolerance. If the VAT is not as expected then the validator will fail.

Image Removed

Set Up:

Tolerance limit of total (%): Minimum value of 0 (if you want it to be exact)

Expected VAT %:   The percentage of the VAT that should be charged, ie 5%.  Written as 5 (not 5%)

GB – ExcessiveNonConsumptionCost Image Removed

Checks bills for excessive electricity non consumption based charges such as standing charges. It will fail validation if the standing charges are greater than those on consumption charges – a tolerance can be applied.

GB - ExVATvsNetCharge.xml 

The excluding VAT charges on the bill do not match the net charges on the Tax Entry tab. This is designed for checking Accounts Links, where the charges must match to the penny, therefore 'Allow Tolerance' option has been added to this validator.

GB – GasBandppu Image Removed

Same as GB – ElecBandppuThreshold but for gas.

GB – GasFixedCharges

Calculates set daily amount for fixed charges based on calculated number of days in the billing period. Fails if the value is higher than the threshold set.

GB – GasInvoicedvsCalc

Same as GB – ElecInvoicedvsCalc but for gas.

Compares the total value of the gas invoice (as calculated by Sigma) against the total value declared on the invoice. It allows for a % difference, if % difference is exceeded then query should be raised.

GB – GasppuThreshold Image Removed

Same as GB – ElecppuThreshold but for gas. There is a set average pence per unit threshold that can be set across all accounts – if exceeded then the validator will fail. 

GB – GasppuvsPropertyKeyExact

Compares a property key against the gas invoice band rate and passes the invoice if the band rate and property key matches. The property keys have the pence per units stored – these are setup on each Account.

GB – GasppuvsPropertyKeyPct

Same as GB – GasppuvsPropertyKeyExact but allows for a tolerance.

GB – GasVAT%Check Image Removed

Checks the expected VAT rate – with the ability to have a % tolerance. If the VAT is not as expected then the validator will fail.

Image Removed

Set Up:

Tolerance limit of total (%): Minimum value of 0 (if you want it to be exact)

Expected VAT %:   The percentage of the VAT that should be charged, ie 5%.  Written as 5 (not 5%)

GB – GreenCCLCheck

Ensures that users of Green electricity are charged at 0% for CCL (Climate Change Levy).

GB – InvoicedvsCalc Image Removed

Compares the total value of the invoice (as calculated by Sigma) against the total value declared on the invoice. It allows for a % difference, if % difference is exceeded then query should be raised.

GB – MDvsAC Image Removed

Compares the maximum demand against the supply capacity and fails if the maximum demand exceeds the supply capacity.

GB – MeterFactorvsPrevious Image Removed

Checks the meter factor matches that of the previous bill.

GB – MeterSerialNumberCheck Image Removed

Checks that the meter serial number on the bill screen and the meter number on the account editor are the same.

GB – TagvsPrevValuePct

Used to compare a particular tag against previous invoice tag. For example, it could be used to compare gas/electricity meter factors on current invoice against previous invoice and will fail if there is a difference. To view the tag of a particular cell in Bill Entry select Tools > Show Tags.

GB – TagvsPropertyKeyPct

Used to compare a contract value against a defined tag (set cell on the bill screen). For example, property key contract price against supply capacity charge (tag).

GB – ValidSupplyPoint Image Removed

Checks to make sure a Supply Point has been setup for an account.

Use this validator to stop an account supplier changing. i.e. if Corona is the gas supplier then you can set the validator at [Corona]; this will stop the bill being saved if the supplier is anyone but Corona.

Image Removed

 Set up: The default ^Unk.|^Unm. stops invoices saving if the supplier is either unknown or unnamed. This default should be entered into the Invalid supplier name pattern.

GB – Waterppu

Sets a threshold for the pence per unit on water invoices; the validator fails if the threshold is exceeded.

GB – WaterppuvsPropertyKeyExact

Compares a property key against the water invoice band rate and passes the invoice if the band rate and property key matches.

GB - WaterVat

Checks the expected VAT rate.

If the VAT is not as expected then the validator will fail.  Generally used to check that the VAT is zero.

It checks tag number 2533 on a water bill (the Calculated VAT field)

Image Removed

Variables:

VAT Limit:  Expected value will be 0

GB – ZeroCCLand5PctVATNEW

Checks that if the VAT is 5% then there is no CCL charge.

GB – ZeroCCLiflessthan33kwh Image Removed

If the average daily consumption is less than 33kWh per day then this validator checks to make sure there is no CCL charged – used on Electricity bills.

GB – ZeroCCLiflessthan145kwh Image Removed

 If the average daily consumption is less than 145kWh per day then this validator checks to make sure there is no CCL charged – use on Gas bills.

GB – ZeroChargeCheck

Normally set as an information only validator. It will fail if the invoice has no charge.

GB – ZeroConsumptionCheck

Normally set as an information only validator. It will fail if the invoice has no consumption. These need to be investigated as these could be possible queries, e.g. closed sites, de-energised, reduction in meter size, etc.

Bill Entry Validators

The Bill Entry (BE) validators apply to manually entered bills only, these are:

BE – AccountLinkBillEditCheck Image Removed

Warns users that there is a second change to a bill.

It applies to bills older than 30 minutes and is used in conjunction with the Accounts Link Activity.  Sigma will automatically save a manual bill after 30 minutes and then when the User completes the bill and saves, the Validator will fail.  If you want the bill to be used in the Accounts Link, you will need to delete the bill and re-enter it so that there isn't a second change.

No additional set up required.

Image Removed

BE – ActivateNewTax Image Removed

Checks that Tax Entry tab is being used to input the VAT (and not the old Tax Summary tab) – particularly important if using the Accounts Link Activity.

EDI bills will automatically use the Tax Entry tab, this Validator is for manual billing.

Accounts Links will specifically look at the Tax Entry tab which is why it is important to have the data in the correct location.

No additional set up required.

Image Removed

BE - BillAttachmentValidator

Identifies when a User attempts to save a manually entered bill without having attached a document (an image of the bill)

BE – BillEntryStopper

Used to stop invoices being saved on inactive accounts – tend to set this validator to severe.

BE – BillInvoiceDateValidator Image Removed

Ensures that an invoice date is entered onto the bill entry screen.

Image Removed

No additional set up required.

BE – BillInvoiceNumber Image Removed

Ensures that an invoice number is being entered.

Image Removed

Set Up:

...

BE – BillReceivedDateValidator Image Removed

Ensures that a received date is entered in the invoice screen.

Image Removed

No additional set up required.

BE – BillThisPeriod Image Removed

Checks to make sure the Bill This Period cell has been populated.

Image Removed

No additional set up required.

BE – ElecUseDeMin & BE – GasUseDeMin Image Removed

Checks whether a value of 1 has been entered in the deminimus cell. Validator will fail if any other value is there. If the 1 is present and the cost of the invoice is not adding up then it may be that CCL has been incorrectly charged.

BE – InvoicedvsCalc Image Removed

This validator compares the invoice cost with the calculated Sigma bill cost and will fail if out of the tolerance threshold.

Image Removed

Set Up:

...

BE – MDentry Image Removed

Used to ensure a maximum demand is entered on to the invoice screen. Works by comparing the maximum demand tag cell against the previous invoice; if the previous invoice is greater than 0, then the validator will fail if maximum demand has not been entered.

BE – WaterVat

Used to ensure that water invoices have 0% VAT.

Image Removed

Set Up:

Variable, VAT Limit:  Enter 0 to ensure VAT isn't charged on a Water Bill

BE – UniqueInvoiceNumberValidator

Checks if the invoice number is unique to that account.

Tenant Billing

The Tenant Billing (TE) validators apply to Tenant Billing only:

TB - HfdChannelGapCheck.xml

Checks for any gaps in Periodic Channel Data

TB - ZeroConsumptionCheck.xml

Checks to see if the consumption is zero

TB - totalConsumptionTol.xml

Checks that the total consumption on this bill is within a set percentage of the previous bill

The percentage is set by the User

TB - totalConsumptionTolYear.xml

Checks that the total consumption on this bill is within a set percentage of the previous years bill

The percentage is set up the User