TB - totalConsumptionTolYearZeroCheck.xml
...
Total cons within % of prev years Tenant Bill. PASS/FAIL on selected bill = zero criteria: FAILED
kWhLimit=10.00 -the 'Pass if cons difference%' figure in the Validator (last field) = 10 - 10 kWh
TolPcent=2.00 - the 'Tolerance' set in the Validator (first field) = 2 - 2%
LoLimit=33.95994 - the consumption in the previous year's bill 33.95994 kWh
...
PresCons=0 - consumption on this bill - 0kWh
However, if the Validator was set to PASS if present bill = zero, previous bill non-zero (bznz), then it would have passed.
An example would be if you did not want to be notified if an Account had zero consumption, even it if had consumption on the previous year's bill.