There are two in this section, one is specifically for Electricity.
- Invoice vs Calculated
- Compares the total value of the invoice (as calculated by Sigma) against the total value declared on the invoice
- Electricity Invoiced Vs Calculated
Compares the total value of the Electricity invoice (as calculated by Sigma) against the total value declared on the invoice
GB – InvoicedvsCalc GB – ElecInvoicedvsCalc
Validator Set Up
Variables
Variable | Description |
---|---|
Bill will pass validation if the Query Value is less than (£) | Enter a monitory figure, for example 0.5 The Validator will only fail if the value of the difference is above 50p, or 5 for £5.00 |
Tolerance value (%) | The percentage you want the invoiced and calculated costs to be within. For example, enter 1 for 1% |
Bill Entry details
Failure Prompt
Invoice Vs Calculated Electricity Invoice Vs Calculated
Invoice cost differs from calculated: FAILED - The name of the Validator
'totalBilledCharge=136.00' - The total charges entered in the Bill this Period field £136.00 (only shows on Electricity Invoice Vs Calculated)
'tolerance=1.00' - The percentage tolerance, ie 1%
'upperthreshold=137.36' - The upper threshold (the value in the Billed this period field, plus 1% - ie £136.00 + £1.36 (1%) = £137.36
'MinimumQueryValue=5.00' - The minimum amount the query needs to be (in £s) for the Validator to fail, ie £5
'lowerthreshold=134.64' - The lower threshold (the value in the Invoice cost field, minus 1% - ie £136.00 - £1.36 = 134.64
'totalCharge=126.00' - The amount in the Invoice cost field (the amount Sigma calculates the bill to be), £126.00
'QueryValue=10.00' - The difference between the Bill this period field and Invoice cost field, ie £136.00 - £126.00 = £10.00