GB – BillReadsAgainstSelfReadChannel 

Compares the invoice meter readings against meter readings entered into Non-Periodic Channels.

Requirements

It looks at the reading values and dates from each channel.

It will accrue from the two previous self-reads to match the most recent bill date, giving an accurate reading of what the self read value would have been on the day the bill was issued.

The Validator requires the following set up:

The Account and the Meter to be in the same Supply Point 

           

The Meter Serial Number to be entered into the Sigma Bill Entry screen

The Meter to have a Non-periodic Channel

Click here to see details on adding a Channel

          


The Non-periodic Channel to have a Property Key (ELECTRIC only)

          


Validator Set up


Variables

VariableDescription
Tolerance limit (%)Enter the required tolerance percentage, ie 10  (for 10%)


Bill Entry screen - Electricity 


Channel Data - Electric

 


Failure Prompt (Electricity)


Electricity Failure Prompt

Self read comparison results: 

Bill read value '15000' differs from self read channel projection '13308.4' -  The meter reading value entered into the present read field (15000) and the projected meter reading from the Non Periodic Channel (13308.4)

(E12345) - The name of the Meter

Explanation

Bill Details

Channel Details

Calculation

35.714 units (the amount of units between dates in the Channel) x 27 (the number of days in the bill) = 964.3 (the predicted advance for the billing period)

964.3 units (the predicted advance for the billing period) added to 12345 (the previous reading in the bill)